Correlation of Pressure Drop along the Length of Channel flow using Modified Delta winglet Vortex Generator
Main Article Content
Abstract
This paper enumerates the pressure drop in a channel flow using a Modified Delta winglet Vortex Generator (MDWVG) by partial correlation. The pressure drop was determined by using Frictional factor (f) that was found significant (p<.05) in correlation to the effect of Modified Delta winglet by using SPSS 16.0 software analysis. The partial correlation was determined to be 0.9 which depicts the close relation between the pressure drop and Reynolds numbers at every point, i.e. Common Flow Down and Common Flow Up configuration at up stream and down stream locations.